![background image](http://html1.mh-extra.com/html/omron/f250-ume/f250-ume_software-manual_743525863.webp)
6-2-(13)
Normal Serial Interface
Section 6-2
6-2-2-1
CLRMEAS: Clear Measure
Function
Clears the measurement values for the current scene.
Input
CLRMEAS Delimiter
Output
Command executed correctly:
OK Delimiter
Command not executed correctly:
ER Delimiter
6-2-2-2
DATASAVE
Function
Saves the current scene group data and system data. (Data for scene group 0
is saved to flash memory, data for scene groups 1 to 31 is saved to the Mem-
ory Card, and the system data is saved to the Memory Card.)
Input
DATASAVE Delimiter
Output
Command executed correctly:
OK Delimiter
Command not executed correctly:
ER Delimiter
Precaution
Do not turn OFF the Controller’s power supply until a response has been
received.
6-2-2-3
DATE
Function 1
Reads the current date and time.
Input
DATE Delimiter
Output
Command executed correctly:
Month Day Hour Minute Year. Second Delimiter
OK Delimiter
Command not executed correctly:
ER Delimiter
Example
This example returns the time and date at 12:30:00 on August, 30 2000.
Input
DATE Delimiter
Output 083012302000.00 Delimiter
OK Delimiter
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...