2-29-(9)
Calculation
Section 2-29
Submenus
The following table shows the processing items that can be used in calcula-
tions.
ATAN
Calculates the arc tangent for the Y component/X component.
The result is given as a radian of
-
pi to pi.
ATAN(Y component, X component)
Example: Set the following to calculate the angle between a
straight line joining the center of gravity for region 0 and the cen-
ter of gravity for region 1 and a horizontal line.
ATAN(R1.Y-R0.Y,R1.X-R0.X)
If both arguments are 0, the calculation result will also be 0 and
the judgement will be NG.
DIST
Calculates the distance between two points, such as the center of
gravity and the center of the model.
DIST(X coordinate of first point, Y coordinate of first point, X coor-
dinate of second point, Y coordinate of second point)
Example: Set the following to calculate the distance between the
center of gravity for region 0 and center of gravity for region 1.
DIST(R0.X,R0.Y,R1.X,R1.Y)
The following calculation is performed internally.
AND
Calculates the LOGICAL AND.
If one of the arguments is 0, the calculation result will be 0. Other
arguments will give
-
1.
AND(argument 1, argument 2)
OR
Calculates the LOGICAL OR.
If both arguments are 0, the calculation result will be 0. Other
arguments will give
-
1.
OR(argument 1, argument 2)
NOT
Calculates the LOGICAL NOT.
If the argument is 0, the calculation result will be
-
1. Otherwise it
will be 0.
NOT(argument)
Function
Meaning
R1.X
R0.X
–
(
)
2
R1.Y
R0.Y
–
(
)
2
+
Classification
Processing item
Page
Position com-
pensation items
Binary position compensation
page 2-29-(11)
EC position compensation
page 2-29-(11)
Edge position compensation
page 2-29-(13)
Model position compensation
page 2-29-(13)
Circle position compensation
page 2-29-(14)
Scroll
page 2-29-(14)
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...