2-14-(21)
Density Defects
Section 2-14
Note Specify Y line under Measurement conditions/measurement direc-
tion.
3.
Changing Detailed Conditions as Required
Change the detailed conditions when the measurement results are unsta-
ble. (Normally, these conditions can be left on the default settings.) After
changing the settings, perform an object measurement to check that mea-
surement can still be performed correctly.
a)
Select Detailed conditions.
The Detailed Conditions Settings Screen will be displayed.
b)
Move the cursor to the condition to be changed and change the set-
ting.
c)
Select End.
The settings will be registered and the screen in (a) will return.
Press the ESC Key to return to the initial screen for Defect (var. box).
Edge Level
Set a density change level between 0 and 100 that will indicate the edge. Nor-
mally, the default setting of 50% will be fine.
The edge is normally detected as follows:
200, 100
70, 100
200, 390
70, 390
Defect or burr
Left edge region
Right edge region
Upper edge region
Lower edge region
Left edge
Measurement conditions
Region
Detailed conditions
Left edge
End
Edge level : [ 50]%
Noise level : [ 20]
Noise width: [ 0]pix
Offset width: [ 0]pix
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...