2-4-(6)
Filtering Again
Section 2-4
1.
Select Filtering.
The settings screen for filtering will be displayed.
If Frame/Field is set to Frame, the filter size will be displayed in the top
right-hand corner of the screen.
2.
Select the filtering method while monitoring the image.
Press the SHIFT + ENT Keys to change the filter size.
3.
Press the ENT Key.
The setting will be registered and the screen in (1.) will return.
CHECK
If the Filtering Again processing item is set to filter the image again, the range
of inaccurate pixels will be doubled. Do not include the outer edges of the
screen when setting the measurement region.
For example:
Filter size of
5
5: -2 pixels
2 = -4 pixels
Filter size of
3
3: -1 pixel
2 = -2 pixels
4.Filtering again
Direction
Filtering order
Filtering
BGS levels
Filtering(Image 0)
SFT+ENT:Filter size
Size3 3
OFF
Weak smoothing
Strong smoothing
Dilate
Erosion
Median
Enhance edges
Extract vertical edges
Screen size
Valid range:
(0,0) to (511,483)
Filter size of 3
3
484
pixels
512 pixels
-2 pixels
Filter size of 5
5
Valid range:
(2,2) to (509,481)
Valid range:
(4,4) to (507,479)
-4 pixels
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...