2-24-(23)
Lot Number OCV 1
Section 2-24
2-24-6
Setting the Inspection Region
Set the region in which numbers are to be extracted.
The setting method depends on the extract mode (automatic/fixed) set as a
measurement condition.
Automatic Extraction Mode
1.
Select Inspected region.
An arrow cursor will be displayed.
2.
Draw the inspected region as a square block.
Specify the upper left and lower right coordinates.
Up/Down/Left/Right Keys: Move the cursor.
ENT Key:
Confirms the setting.
CHECK
Draw the region so that only the target numbers fall within the region. Use
End Image to remove anything other than the target numbers that overlap
either vertically or horizontally on the inspected region.
SeeAlso
Refer to page 2-24-(13).
If the edges overlap both vertically and horizontally, the numbers cannot be
extracted correctly. If the edges overlap in both directions, adjust the posi-
Inspected region
Set one inspected region.
The numbers will be automatically extracted from
this region. The following settings are used when
extracting.
Extract conditions/Extraction method: page 2-24-
(9)
Extract conditions/Dilate level: page 2-24-(12)
Extract conditions/Noise conditions: page 2-24-(13)
1.Lot-No. OCV1
Measurement image
Extract conditions
Font
Measurement conditions
Reference date
Inspected region
Judgement conditions
Reference number
Inspected region
35,175
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...