2-25-(6)
Labeling
Section 2-25
2-25-3
Setting Measurement Conditions
Set the Area, Sort, and Label No. as conditions for label measurement.
Change the other settings as well when necessary.
CHECK
The coordinates set using calibration are not affected by labeling.
CHECK
When Position compensation is set, the sort is performed on center of gravity
coordinates after position compensation.
1.
Select Measurement conditions.
Measurement conditions
End
Area range for labels (0 to 9,999,999.999 (0*))
Output conditions for measurement value:
OFF*: Outputs area and center of gravity
coordinates before filling holes.
ON:
Outputs area and center of gravity
coordinates after filling holes.
Output conditions for measurement value:
OFF*: Measures the binary image.
ON:
Measures all pixels outside the
measurement region as white pixels.
Label No. for data output (0 to 2,499 (0*))
Area :
[ 0.000 :
247808.000 ]
Outside trimming : OFF
Filling up holes : OFF
Sort :
Area descending order
Label No. : [ 0]
The asterisk (*) indicates the default setting.
Conditions for reassigning label numbers
Area descending order:*
Area ascending:
X coordinate descending:
X coordinate ascending:
Y coordinate descending:
Y coordinate ascending:
Sorts in descending order by area.
Sorts in ascending order by area.
Sorts in descending order by center of gravity X coordinate. (See note.)
Sorts in ascending order by center of gravity X coordinate. (See note.)
Sorts in descending order by center of gravity Y coordinate. (See note.)
Sorts in ascending order by center of gravity Y coordinate. (See note.)
Note When X and Y center of gravity are sorted, the upper left corner of the measurement region
is the origin.
Sort example:
0
X
Y
Labeling result
Label numbers in
descending order
by area
Label numbers in
ascending order by
X center of gravity
0
2
2
0
1
1
0
2
1
Label numbers in
descending order by
Y center of gravity
Measurement image
Binary
Measurement conditions
Region
Reference registration
Judgement conditions
Coordinate mode
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...