![background image](http://html1.mh-extra.com/html/omron/f250-ume/f250-ume_software-manual_743525065.webp)
1-(57)
Basic Operations
Section 1-6
HELP
Handling Images for Fine Matching
When Fine Matching is executed, the differential image (where only the differ-
ence between the model and inspection images has been extracted) is stored
as Image 1.
If Image 1 is to be used for measurement for subsequent units, set Change Fil-
tering before the next processing item and obtain the image stored in the
image buffer again.
0.Camera image
1.Fine matching
2.Change Filtering
3.Binary defect
0.Scn 0=SET=
Fine matching uses Image 0 for
measurement
Camera
setting
Camera
0
Camera
1
Camera
2
Camera
3
Image buffer
(for Camera 0)
Image buffer
(for Camera 1)
Image buffer
(for Camera 2)
Image buffer
(for Camera 3)
Camera
selection
Filter
0
Filter
1
Image 0
Image 1
The differential image is stored
after fine matching is executed.
Setting Example
Image 1 to be used for
measurement
Image obtained again from image buffer
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...