2-17-(8)
Edge Position
Section 2-17
3.
Press the ENT Key.
The setting will be registered and the screen in (1.) will return.
STEP 4: Setting Judgement Conditions
Set the position ranges for an OK judgement.
CHECK
Position X and Position Y will change depending on the settings under Mea-
surement/Direction.
The origin and coordinate system are determined by the calibration settings.
1.
Select Judgement conditions.
The Judgement Conditions Settings Screen will be displayed.
2.
Change the settings.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
Judgement conditions
End
Position X : 95.000
Range for X coordinates
(-9,999.999 to 9,999.999)
Measurement results for displayed image
Range for an OK judgement
[ 0.000 :
511.000
]
Position Y : 95.000
[ 0.000 : 511.000
]
Range for Y coordinates
(-9,999.999 to 9,999.999)
The X coordinate is set when
←
and
→
are selected.
The Y coordinate is set when
↑
and
↓
are selected.
Y
X
Region0
Measurement conditions
Region
Reference registration
Judgement conditions
Detailed conditions
Clear
Judgement conditions
End
Position X: 95.000
[ 0.000 :
511.000
]
Position Y: 95.000
[ 0.000 : 511.000
]
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...