2-40-(3)
DO Judgement
Section 2-40
2-40-2
Setting Output Details
Use expressions to set the output data.
For each unit, 32 expressions (0 to 31) can be set.
1.
Select DO judge.
A list of set expressions will be displayed.
2.
Select the output number to which the expression will be set.
Judge0.
ENT:Change
U2.R00X-U2.R01X
Measurement : 578908.965
Upper : [ 600000.000]
Lower : [ 550000.000]
Output number
Judge 0 to 31
Expression
Measurement result for set expression
Use as reference for judgement conditions.
Judgement conditions
Set the judgement conditions for the
expression. Set the OK range between
-9,999,999.999 and 9,999,999.999.
0.Camera image
1.Binary pos. comp
2.Edge position
3.Edge position
4.DO judge
5.
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
4.DO judge
Conditions
0.
1.
2.
3.
4.
5.
6.
SFT+ESC:Edit
Output number