![background image](http://html1.mh-extra.com/html/omron/f250-ume/f250-ume_software-manual_743525782.webp)
4-(28)
Checking I/O Status with External Devices
Section 4-5
4-5
Checking I/O Status with External Devices
Use the I/O monitor function to check the communications status via serial or
parallel interfaces. Wiring and communications settings can be checked to see
if they are correct.
4-5-1
Serial Interface
The communications status via the serial interface can be checked.
1.
Display the Basic Screen for Monitor Mode or Run Mode.
2.
Move the cursor to MON (or RUN) and press the ENT Key.
The mode selections will be displayed.
3.
Select TOOL.
The tool selections will be displayed.
Down Key: Scrolls through the menu.
4.
Select I/O monitor.
The interface selections will be displayed.
Image 0 freeze
---- ---ms
0.Scn 0
MON
---- ---ms
0.Scn 0
MON
SET
MON
RUN
SYS
TOOL
SAVE
TOOL
Scn Group
Image data
Memory card
Clear images
Clear measurement
Line brightness
I/O monitor
Back up Flash memory
Serial
Parallel
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...