Density Defects
Section 2-14
2-14-1
Selecting Measurement Images
When Defect (Line), (Circum), (Arc), (Region), (Var. box) is set for the inspec-
tion region, select which image will be used for measurement, the image
stored at Image 0 or the image stored at Image 1.
CHECK
Select Image 0 if any one of the 8 regions has Defect (deviation) registered.
Defect (deviation) uses the image stored at Image 0 for measurement.
1.
Select Density defect.
The initial Density Defect Screen will be displayed.
2.
Select Measurement image.
The selections will be displayed.
3.
Select Image 0 or Image 1 to use either of the images stored at these lo-
cations for measurement.
4.
Press the ENT Key.
The settings will be registered and the screen in (1.) will return.
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
0.Camera image
1.Density defect
2.
1.Density defect
Measurement image
Select region
Coordinate mode
Measurement image
Image0
Image1