2-12-(10)
Detecting Binary Defects
Section 2-12
Fill Profile Function
The fill profile function is set when the exterior of the measurement object is
being measured.
Turn ON the fill profile function to measure the whole area between the start
point (black pixels to white) and the end point (white pixels to black) in the
measurement region as white pixels.
Example
When a White-pixel Section Encroaches on the Measurement Region
Measuring Open-form Measurement Objects
Measurement region
Start point End point
This area will be measured as white pixels.
Fill profile: ON
Input image
Measurement region
Measurement region
Fill profile: ON
Input image
Not recognized as start point because change from white to black.
Fill profile: ON
Input image
The measurement result changes depending on the orientation of the measurement
object.