2-12-(4)
Detecting Binary Defects
Section 2-12
2-12-2
Setting the Binary Level
Set the level for converting 256-gradation images into binary images. Mea-
surements are performed for the white pixels. Therefore, make the settings so
that the measurement object is white.
The binary level set here is used for all of the measurement regions.
CHECK
The binary levels can be set for each measurement region.
1.
Select Binary defect.
The setting selections will be displayed.
2.
Select Binary (Common).
The settings screen for binary levels will be displayed.
0.Camera image
1.Binary defect
2.
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
1.Binary defect
Measurement image
Binary(Common)
Select region
Coordinate mode
:Move :Change
Binary level
Reverse
Auto
OK
Upper[
255
]
Lower[128]
Upper limit
Lower limit
Auto
The Controller
automatically
determines binary level.
Reverse
Reverses black and white display.