2-15-(23)
EC Defect
Section 2-15
2-15-3-3
Removing Lines with Line Angle Specified
The direction of the line and the permissible range are set and only the lines
within that range are removed.
Correct measurement cannot be performed if the measurement object has
rotated. Therefore, if position displacement occurs, set position displacement
compensation earlier than the unit for which EC defect inspection is set.
HELP
Oriented Line Extracting Algorithm Using Edge Codes
1.
An edge code image is created.
Points with edge codes within the permissible range are detected as edges
on the line.
1
2
180
°
+10
°
−
10
°
Set the
removal
region.
Set the
direction.
Example
Outline of measurement object
(This line to be removed.)
Defect
(Only this is to be detected.)
Set the direction and permissible range.
Lines with edge codes
within the permissible
range will be removed.
The defect is not within
the range and will,
therefore, remain.
Original image
Set permissible range.
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...