3-(6)
Starting Measurement
Section 3-2
3-2-2
Performing Measurement
Use the following procedure to execute measurement according to the condi-
tions set for the scene currently displayed. The measurement results will be
output to external devices as well.
Press the TRIG Key on the Console or input the measurement command from
an external device.
Note
A through display requires longer measurement time than a freeze display.
• Frame: 16.7 ms max.
• Field:
8.3 ms max.
Measurement will be executed and the measurement results will be displayed
on the screen.
CHECK
The key operations are the same as for Monitor Mode.
SeeAlso
Refer to
7HVW0HDVXUHPHQW
for details.
CHECK
The lighting will become progressively darker if used for long periods. Make
periodic adjustments to the judgement conditions. When Intelligent Lighting is
used, the lighting will lose approximately 20% illumination after 1,500 hours of
use.
OK 67ms
Image 0 freeze
0.Scn 0
RUN
Overall judgement
Measurement time (see note)