6-2-(81)
Normal Serial Interface
Section 6-2
CHECK
Only the allocations for region 0 are listed here. Refer to the allocations for
region 0 and calculate the numbers for regions 1 to 3.
Rotation Positioning (Measurement Data)
Settings
data
1065
Region 1
Mode
0: Fixed region
1: Auto extraction
to
... (Same as for region 0)
1154
Region 2
Mode
0: Fixed region
1: Auto extraction
to
... (Same as for region 0)
1243
Region 3
Mode
0: Fixed region
1: Auto extraction
to
... (Same as for region 0)
1331
Fixed 20th character Lower right Y coordinate (0
to 483)
1332
Ring characters (0: 0, 1: O)
Data
Details
Data
Details
Measure-
ment
data
0
Judgement result
-2: Not measured.
-1: NG
0: OK
1
Region 0
Judgement result
2
Correlation
3
Position X
4
Position Y
5
Angle
6
Reference position X
7
Reference position Y
8
Region 1
Judgement result
to
... (Same as for region 0)
50
Region 7
Judgement result
51
Correlation
52
Position X
53
Position Y
54
Angle
55
Reference position X
56
Reference position Y
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...