2-17-(9)
Edge Position
Section 2-17
STEP 5: Changing Detailed Conditions
Change the detailed conditions when the measurement results are unstable.
Normally, these conditions can be left on the default settings. After changing
the settings, perform an object measurement to check that measurement can
still be performed correctly.
1.
Select Detailed conditions.
The Detailed Conditions Settings Screen will be displayed.
2.
Change the settings.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
Edge Level
Set a density change level between 0 and 100 that will indicate the edge. Nor-
mally, the default setting of 50% will be fine.
The edge is normally detected as follows:
1.
The density distribution of the whole measurement region is calculated.
2.
The density difference between the lowest and highest density value be-
comes 100%.
3.
The point where the edge level density change is detected becomes the
edge.
Region0
Measurement
conditions
Region
Reference registration
Judgement conditions
Detailed conditions
Clear
Detailed conditions
End
Edge level : [ 50]%
Noise level : [ 20]
Noise width : [ 0]pix
Maximum density value
Edge level
Minimum density value
100%
50%
0%
Measurement region
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...