6-2-(95)
Normal Serial Interface
Section 6-2
Trend Monitor (Settings Data)
Branching Control
Branching (Measurement Data)
Data
Details
Settings
data
17
Judgement lower limit (-9,999,999.999 to 9,999,999.999)
18
Judgement upper limit (-9,999,999.999 to 9,999,999.999)
19
Warning lower limit (-9,999,999.999 to 9,999,999.999)
20
Warning upper limit (-9,999,999.999 to 9,999,999.999)
21
Display range lower limit (-9,999,999.999 to 9,999,999.999)
22
Display range upper limit (-9,999,999.999 to 9,999,999.999)
23
Recording interval (1 to 99,999)
24
Warning count (1 to 999)
25
Display average
0: ON
1: OFF
26
Display maximum
0: ON
1: OFF
27
Display minimum
0: ON
1: OFF
28
NG by warning
0: ON
1: OFF
29
Graph line
0: 1 dot
1: 2 dot
Data
Details
Measure-
ment
data
0
Judgement result
-2: Not measured.
-1: NG
0: OK
1
Expression A
2
Expression B
3
Evaluation result
4
Destination