2-23-(3)
ECM Search
Section 2-23
2-23-1
Selecting Measurement Images
This section describes how to select an image stored at either Image 0 or
Image 1 as the image for measurement.
CHECK
The edges are extracted for the image number selected here and this image is
then stored at the other image number. Set Change Filtering as the next pro-
cessing item to use this image for measurement for all units after the unit for
which ECM search was set. Then store the image stored in the image buffer to
Image 0 or Image 1.
When Image 0 Is Selected as Measurement Image
1.
Select ECM search.
The initial ECM Search Screen will be displayed.
2.
Select Measurement Image.
The selections will be displayed.
3.
Select which image will be used for measurement, the image stored at Im-
age 0 or the image stored at Image 1.
0.Camera image
1.ECM search
2.Change filtering
3.Binary defect
4.
0.Scn 0=SET=
Image
0
Image
1
Edge extraction
Edge-extracted image
stored to Image 1.
Image 1 used for measurement.
Image read from image buffer again.
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
0.Camera image
1.ECM search
2.
Measurement image
Extract edges
Measurement conditions
Model registration
Search coordinate
Search region
Judgement conditions
Detailed conditions
Coordinate mode
Measurement image
Image0
Image1
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...