2-15-(45)
EC Defect
Section 2-15
The Judgement Conditions Settings Screen will be displayed.
2.
Change the settings.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
STEP 5: Changing Pixel Skipping
To shorten measurement processing time, change the number of pixels to be
skipped. The greater the skipping setting, the shorter the processing time.
However, the accuracy of the measurement will decrease.
Once the skipping setting has been changed, perform a measurement and
confirm that measurement can be performed correctly.
Skipping X and Skipping Y
Set how many pixels to skip in the inspected region during measurement. The
default setting is 1, which means that all of the measurement region will be
measured.
1.
Select Detailed conditions.
Judgement conditions
End
Area : 2035.000
[ 200.000 : 247808.000]
Gravity X : 180.000
[ 0.000 : 511.000]
Gravity Y : 250.000
[ 0.000: 483.000]
Skipping X
Skipping Y
Pixel
Inspected R0(Gravity and area)
Binary
Measurement conditions
Inspected region
Judgement conditions
Detailed conditions
Clear
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...