2-24-(8)
Lot Number OCV 1
Section 2-24
1.
Select Binary.
The settings screen for binary levels will be displayed.
2.
Move the cursor to the upper limit and use the Left and Right Keys to
change the value.
Right Key:
Increases the lowest digit by one.
SHIFT+Right Keys: Increases the value 10 times faster.
Left Key:
Decreases the lowest digit by one.
SHIFT+Left Keys:
Decreases the value 10 times faster.
Up and Down Keys: Switches between setting items.
3.
Use the same method to change the lower value.
CHECK
Set the upper and lower limits so that the numbers are displayed as white
pixels.
4.
Select OK.
The settings will be registered and the screen in (1.) will return.
CHECK
It is also possible to set the binary level so that measurement is performed
only for an intermediate density range.
Extract conditions
Compensate image
Shading
Binary
Extract method
Dilate level
Noise conditions
:Move :Change
Binary level
Reverse
Auto
OK
Upper[
255
]
Lower[128]
Lower limit
Upper limit
Auto
The Controller automatically
sets the binary level.
Reverse
Reverses white or black in
the display.
:Move :Change
Binary level
Upper[255]
Lower[128]
Reverse
Auto
OK
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...