![background image](http://html1.mh-extra.com/html/omron/f250-ume/f250-ume_software-manual_743525611.webp)
2-27-(5)
Edge Pitch
Section 2-27
2-27-3
Drawing Measurement Regions
Draw a region to include all the edges to be detected.
CHECK
Edges are detected in the direction of the long side of the measurement
region.
1.
Select Region.
The Region Settings Screen will be displayed.
2.
Draw a box-shaped measurement region.
CHECK
The only figure that can be drawn is a box.
When the bottom right coordinates have been set, the screen in (1.) will re-
turn.
Measurement
region
Detection
direction
5 edges
0 edges
Measurement
region
Detection
direction
Correct
Incorrect
Measurement image
Measurement conditions
Region
Judgement conditions
Detailed conditions
Coordinate mode
Region
450,373