2-15-(33)
EC Defect
Section 2-15
CHECK
Only parallel lines that match the set defect width and length will be detected
as defects. Width and length conditions can be set to exclude measurement
outlines from being detected as defects, even if the outline is box-shaped and
the edges are parallel.
1.
Select Inspected regions.
A list of inspected regions will be displayed.
2.
Select a region number.
The measurement method selections will be displayed.
3.
Select Defect.
The initial Defect Screen will be displayed.
4.
Select Measurement conditions.
The Measurement Conditions Settings Screen will be displayed.
1.EC defect
Measurement image
Extract edges
Removal regions
Removal image
Inspected regions
Coordinate mode
Inspected regions
Region0
Region1
Region2
Region3
Region4
Region5
Region6
Region7
Defect
Labeling
Gravity and area
Measurement conditions
Inspected region
Clear
Measurement conditions
Extracting level : 3
Defect color : Black
Defect width : [ 1:10]pix
Defect length : [ 1:50]pix
End
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...