6-1-(15)
Parallel Interface
Section 6-1
Note
Use DI8 to DI15, in addition to DI0 to DI4, when setting re-registration of mod-
els for units 31 and later.
SeeAlso
Refer to
,2)RUPDW
.
CHECK
The ERR signal will turn ON if the input command was not received correctly.
DI6
ON
DI7
DI7 is the execution trigger.
After DI0 to DI6 and DI8 to DI15 are set, allow at least 1 ms before turning
ON DI7. The BUSY signal will be ON while the command is being exe-
cuted.
After confirming that the BUSY signal is ON, turn OFF DI7, and finally turn
OFF DI0 to DI6 and DI8 to DI15.
Signal
Function