5-(23)
Customizing Operations
Section 5-4
5-4-3
Shortening Scene Group Switching Time
Normally, settings data is saved to flash memory and the Memory Card when
scene groups are changed. The time taken to save is, therefore, added to the
time taken to change scene groups. The time to change scene for changes in
measurement setups can be reduced by omitting the save process.
Precaution
If this function is set to OFF and settings data changed, always save the data
before changing scene groups. When scene groups are changed, data from
the flash memory or the Memory Card is loaded. So if the changed settings
data is not saved, the data will be replaced by the loaded data. Refer to
6(&
7,212WKHU)XQFWLRQV
.
1.
Enter System mode and select Operation settings.
SeeAlso
Refer to
(QWHULQJ6\VWHP0RGH
.
The Menu will be displayed.
2.
Select Save at switch Scn Group.
The Saving at Switch Scn Group Settings Screen will be displayed.
3.
Select ON or OFF.
ON: Saves the data (default)
OFF: Does not save the data
4.
Select End.
The setting will be saved and the screen in (1.) will return.
Set key operation
Display capture
Save at switch Scn Group
Password
Nonstop/Fast
End
Saving at switch Scn Group
Save :
ON
OFF
ON
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...