2-11-(3)
Scroll
Section 2-11
2-11-1
Setting the Reference
Set expressions to specify the units and measured values to be used as the
reference for scrolling.
Example: Scrolling Using Labeling in Unit 1 as the Reference
Measure X
Measure Y
Measure
Reference X
Reference Y
Reference
Judgement conditions
:
:
:
:
:
:
2.Scroll
Value of this expression is reference position for scrolling in X direction.
Image scrolled in Y direction for difference between reference Y and value of this expression.
Image scrolled rotationally for difference between reference
q
and value of this expression.
Value of this expression is reference position for scrolling in Y direction.
Image scrolled in X direction for difference between reference X and value of this expression.
Value of this expression is reference position for scrolling rotationally.
1.
0.
2.
Measure X
Measure Y
Measure
Reference X
Reference Y
Reference
Judgement conditions
:
:
:
:
:
:
2.Scroll
Gravity X of Unit 1
Gravity Y of Unit 1
Reference X of Unit 1
Reference Y of Unit 1
Camera image
Noise
Label 0 (largest area)
Labeling
Areas are assigned label
numbers in descending order of
area. Label 0 is set for output.
Scrolling is performed
using the center of gravity
X and Y of label 0.
Scroll
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...