2-25-(13)
Labeling
Section 2-25
2-25-6
Setting Judgement Conditions
Set the ranges for the number of labels, area and center of gravity for an OK
judgement.
1.
Select Judgement conditions.
The Judgement Conditions Settings Screen will be displayed.
2.
Make the settings for each item.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
Judgement conditions
End
Range for specified label number area (0 to 9,999,999.999)
Range of movement in X direction for
specified label number (-9,999.999 to 9,999.999)
Range of movement in Y direction for
specified label number (-9,999.999 to 9,999.999)
Range for number of labels in measurement region (0 to 2,500)
: Measurement results for the displayed image.
Use these values as references for setting upper and lower limits.
Ranges for an OK judgement
Number of labels : 8 [ 0: 2500]
Judge area : 2035.000
[ 0.000 :
247808.000
]
Gravity X : 26.000
[ 0.000 : 511.000]
Gravity Y :157.000
[ 0.000 : 483.000]
Measurement image
Binary
Measurement conditions
Region
Reference registration
Judgement conditions
Coordinate mode
Judgement conditions
End
Number of labels : 8 [ 0: 2500]
Judge area : 2035.000
[ 2000.000 :
2300.000
]
Gravity X : 26.000
[ 0.000 : 511.000]
Gravity Y :157.000
[ 0.000 : 483.000]
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...