2-14-(25)
Density Defects
Section 2-14
2.
Use the Up/Down/Left/Right Keys to move the cursor to change the ref-
erence position.
3.
Press the ENT Key.
A display cursor will appear at the position where a small defect was found.
4.
Use the Up/Down/Left/Right Keys to move the cursor to change the ref-
erence position as for large defects and Press the ENT Key.
The settings will be registered and the screen in (1.) will return.
STEP 4: Setting Judgement Conditions
Set the conditions for determining defects. Set a value between 0 and 255 as
the OK judgement value. Measure several samples and set the judgement
conditions while referring to the measurement results.
1.
Select Judgement conditions.
251,200
Reference registration
ENT:Set :Move
Reference position for small defect
End
:
Judgement conditions
128[
30
]
128[ 30 ]
250[255 ]
180[ 0 ]
:
:
:
:
Large defect
Small defect
Density Max.
Density Min.
Set the upper limit for an OK judgement.
(The lower limit is fixed to 0.)
Example: When judgement value set to 30:
Measurement results in the range 0 to 30 will
give an OK judgement.
Measurement result for the displayed image
Use as a reference for setting conditions.
Region0(Defect(var.box))
Measurement conditions
Left edge
Upper edge
Right edge
Lower edge
Reference registration
Judgement conditions
Detailed conditions
Clear
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...