![background image](http://html1.mh-extra.com/html/omron/f250-ume/f250-ume_software-manual_743525212.webp)
2-9-(9)
Circle Position Compensation
Section 2-9
2-9-1-2
1 Model
Position displacement compensation can be performed in the rotation direction
by registering a characteristic feature as the rotation positioning model.
Setting Measurement Conditions
Set the conditions for searching for the rotation positioning model.
A search is performed using a model that rotates in skipping angle (*2) incre-
ments within the rotation range (*1).
The asterisk (*) indicates the default setting.
4
2
3
1
Set
judgement
conditions.
Register
models.
Set search
region.
Set
measurem
ent
conditions.
Model 3
Model 1
Model 4
Model 0
Model 2
Reference angle
Rotation positioning
model
*1
*2
End
Rotation range:
Skipping angle:
None
6
Setting
item
Selections
Details
Rotation
range
None*
5
15
30
45
0
15
, 180
15
0
30
, 180
30
All angles
Select the range
for model rotation.
Example: Rotation range:
30
, Skipping angle: 15
Creates a model that rotates 15
at a time between
-
30
and 30
.
(Coordinate system: Left-hand)
Skipping
angle
1
10
2
15
3
20
5
30
6
*
Select the skip-
ping angle for the
model. The
smaller the angle,
the more precise
the search. Pro-
cessing time,
however, will be
longer.
−
30
°
−
15
°
0
°
+15
°
+30
°
Image
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...