SPECIFICATION

Temperature Stability:

50 ppm/°C

Display:

4-digit, 7-segment LED, 57.2mm (2.25”)
with red, green and amber programmable 
colors.

Alarm:

Alarm 1 & 2 programmable, 
Latch/Unlatch, High, Low, High/Low

SERIAL INTERFACE

Communication Standard:

RS-485, RS-422 or RS-232

Transfer speed (Baud rate):

300, 600, 1200, 2400, 4800, 9600,
19200 bps

Data Format:

7O1-7 bit, Odd, 1 stop bit, 7E1- 7 bit,
even, 1 stop bit
8N1 – 8 bit, No parity, 1 stop bit

Multi-Point Address (RS-485):

0 to 199

Flow Control:

No Flow control

Screw terminals for RS-232/485/422
interface

Power Supply:

100-240 Vac ±10%, 50/60 Hz, 22.5 W

Operating Temperature:

0 to 40°C

Storage Temperature:

-20 to 60°C

Relative Humidity:

0 to 85%

Protection:

NEMA-4x (IP65)

Dimensions:

298 L x 137 W x 73 D mm
(11.75" x 5.375" x 2.875")

Panel Cutout:

279.4 L x 116.8 W mm
(11.00” L x 4.60” W)

Weight:

1,360 g (3 lbs)

Approvals:

CE per EN61010-1:2001

DISPLAY ABBREVIATIONS

ALR1

Alarm 1 Status

OFF

Alarm 1 set Off

ON

Alarm 1 set On

A1Md

Alarm 1 Mode

A1LO

Alarm 1 Low

A1HI

Alarm 1 High

A1LH

Alarm 1 Low/High

LO-1

Alarm 1 Low

-999..

Alarm 1 Low Value

..9999

HI-1

Alarm 1 High

-999..

Alarm 1 High Value

..9999

A1CR

Display color when Alarm 1 triggered

GRN

Green Color

REd

Red Color

AMbR

Amber Color

ALR2

Alarm 2 Status

OFF

Alarm 2 set Off

ON

Alarm 2 set On

A2Md

Alarm 2 Mode

A2LO

Alarm 2 Low

A2HI

Alarm 2 High

A2LH

Alarm 2 Low/High

LO-2

Alarm 2 Low

-999..

Alarm 2 Low Value

..9999

HI-2

Alarm 2 High

-999..

Alarm 2 High Value

..9999

A2CR

Display color when Alarm 2 triggered

GRN

Green Color

REd

Red Color

AMbR

Amber Color

OUt

Alarm Latched/Unlatched selection

LAtC

Latched

UNLA

Unlatched

NO.CR

Display Color in Normal condition

GRN

Green Color

REd

Red Color

AMbR

Amber Color

MOdE

Data Flow Mode

HOSt

Host Mode

SLAV

Slave Mode

bAUd

Baud Rate

300..

Baud Rate Value

..19200

FORM

Data Format

7O1

7 Bit, Odd,

7E1

7 Bit, Even, 

1 Stop Bit

1 Stop Bit

8N1

8 Bit, No parity,
1 Stop Bit

COMM

Communication Standard

232

RS-232 Standard

485

RS-485 Standard

AddR

Device Address

0000..

Address Value

..0099

INtF

Interface Device

dRNt

DRN with 

dRNP

DRN with 

Temperature Input

Process Input 

Miscellaneous:

PEAk

Peak Value

VALL

Valley Value

PROC

Process Value

RUN

Run Mode

OVLd

Input Overload

StOR

Stored Message

1. In 

Slave

Mode the Big Display will wait for

commands and data from the Serial Bus.

2. In 

Host

Mode the Big Display will send data

automatically and continuously into the Serial Bus.

3. When used in 

RS-485

Mode, the device must be

accessed with an appropriate 

Address

Value.

4. 

Latched

Mode: Alarm remains latched until reset. 

To reset already latched alarm select any menu 
items and then press “up” or “down” button.

FLOW 

CHART

_____Underline 

denotes 

factory 

default 

setup

Below 

is 

flowchart 

showing 

how 

to 

navigate 

through 

all 

menus 

by 

pressing 

front 

buttons.

a

aa

a

aa

a

d

d

d

d

d

d

d

d

c

b

c

b

c

b

c

b

c

b

c

b

d

d

c

bd

c

bd

d

d

d

d

a

d

c

b

d

a

a

dd

d

a

c

b

c

b

dd

d

a

a

d

c

b

d

c

b

a

dd

d

a

c

b

c

b

dd

d

a

a

d

c

b

d

c

b

d

a

c

b

d

bc

c

b

c

b

c

b

c

b

M4191/0405

USA

MADE IN

iLD24-C2

Big Remote Display

with RS-232 Input

OPERATION MANUAL

Servicing North America:

USA:

 

 

         One Omega Drive, P.O. Box 4047

ISO 9001 Certified

 

         Stamford CT 06907-0047

 

 

         TEL: (203) 359-1660 

 

FAX: (203) 359-7700

 

 

         e-mail: [email protected]

Canada:

   

         976 Bergar

 

 

         Laval (Quebec) H7L 5A1

 

 

         TEL: (514) 856-6928 

 

FAX: (514) 856-6886

 

 

         e-mail: [email protected]

For immediate technical or application assistance:

USA and Canada:

           Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

®

 

 

         Customer Service: 1-800-622-2378 / 1-800-622-BEST

®

 

 

         Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

®

Mexico and

  

         TEL: (001)800-TC-OMEGA

®

 

FAX: (001) 203-359-7807 

Latin American: 

         

En Espa

ñ

ol: (001) 203-359-7803 

 

 

         e-mail: [email protected]

Servicing Europe:

Benelux:

  

         Postbus 8034, 1180 LA Amstelveen, The Netherlands

 

 

         TEL: +31 20 3472121 

 

FAX: +31 20 6434643

 

 

         Toll Free in Benelux: 0800 0993344 

 

 

         e-mail: [email protected]

Czech Republic:

 

         Frystatska 184, 733 01 Karviná

 

 

         TEL: +420 59 6311899   

FAX: +420 59 6311114

 

 

         e-mail: [email protected]

France:

   

         11, rue Jacques Cartier, 78280 Guyancourt

 

 

         TEL: +33 1 61 37 29 00  FAX: +33 1 30 57 54 27

 

 

         Toll Free in France: 0800 466 342

 

 

         e-mail: [email protected]

Germany/Austria:

           Daimlerstrasse 26, D-75392 Deckenpfronn, Germany

 

 

         TEL: +49 7056 9398-0   

FAX: +49 7056 9398-29

 

 

         Toll Free in Germany: 0800 639 7678

 

 

         e-mail: [email protected]

United Kingdom:

           One Omega Drive

ISO 9002 Certified

 

         River Bend Technology Centre

 

 

         Northbank, Irlam  Manchester M44 5BD United Kingdom  

 

 

         TEL: +44 161 777 6611  FAX: +44 161 777 6622

 

 

         Toll Free in England: 0800 488 488

 

 

         e-mail: [email protected]

OMEGAnet

®

 On-Line Service

www.omega.com

Internet e-mail

[email protected]

®

®

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of

one (1) year

from the date of purchase. In addition to OMEGA’s standard warranty period, OMEGA Engineering will

extend  the  warranty  period  for 

four (4)  additional  years

if  the  warranty  card  enclosed  with  each  instrument  is

returned to OMEGA.

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will
issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA,
if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply
to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing,
operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit
shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive
corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions  outside  of  OMEGA’s  control.  Components  which  wear  are  not  warranted,  including  but  not  limited  to
contact points, fuses, and triacs.

OMEGA is  pleased  to  offer  suggestions  on  the  use  of  its  various  products.  However,  OMEGA neither
assumes responsibility for any omissions or errors nor assumes liability for any damages that result from
the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA
warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO
OTHER  WARRANTIES  OR  REPRESENTATIONS  OF  ANY KIND  WHATSOEVER,  EXPRESS  OR  IMPLIED,
EXCEPT  THAT  OF  TITLE,  AND  ALL IMPLIED  WARRANTIES  INCLUDING  ANY WARRANTY OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION
OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with
respect  to  this  order,  whether  based  on  contract,  warranty,  negligence,  indemnification,  strict  liability  or
otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event
shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS:    Equipment  sold  by  OMEGA is  not  intended  to  be  used,  nor  shall  it  be  used:  (1)  as  a  “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications
or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application,
used  on  humans,  or  misused  in  any  way,  OMEGA assumes  no  responsibility  as  set  forth  in  our  basic
WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless
from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct  all  warranty  and  repair  requests/inquiries  to  the  OMEGA Customer  Service  Department.  BEFORE
RETURNING ANY PRODUCT(S)  TO  OMEGA,  PURCHASER  MUST OBTAIN AN AUTHORIZED  RETURN  (AR)
NUMBER  FROM  OMEGA’S  CUSTOMER  SERVICE  DEPARTMENT (IN  ORDER  TO AVOID  PROCESSING
DELAYS).  The  assigned AR  number  should  then  be  marked  on  the  outside  of  the  return  package  and  on  any
correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in
transit.  

FOR WARRANTY RETURNS, please have the
following information available BEFORE 
contacting OMEGA:
1.

Purchase Order number under which the product
was PURCHASED,

2.

Model and serial number of the product under
warranty, and

3.

Repair instructions and/or specific problems
relative to the product.

FOR NON-WARRANTY REPAIRS, consult OMEGA for
current repair charges. Have the following information
available BEFORE contacting OMEGA:
1. 

Purchase Order number to cover the COST of the
repair,

2.

Model and serial number of product, and

3.

Repair instructions and/or specific problems
relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.

© Copyright 2002 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without
the prior written consent of OMEGA ENGINEERING, INC.

PATENT AND TRADEMARK NOTICE: This product is covered by one or more of the following patents:  U.S. Pat.
No. Des. 336,895; 5,274,577; 6,243,021/ CANADA 2052599; 2052600/ ITALY 1249456; 1250938/ GERMANY DE 41
34398 C2/ SPAIN 2039150; 2048066/ UK Patent No. GB2 249 837; GB2 248 954/ FRANCE BREVET NO. 91 12756.
Other U.S. and International Patents pending or applied for.

This  device  is  marked  with  the  international  caution  symbol.      It  is  important  to  read  the
Setup Guide before installing or commissioning this device, as the guide contains important
information relating to safety and EMC.

WARNING:

These  products  are  not  designed  for  use  in,  and  should  not  be  used  for,  patient-

connected applications.

It  is  the  policy  of  OMEGA to  comply  with  all  worldwide  safety  and  EMC/EMI  regulations  that  apply.
OEMGA is constantly pursuing certification of its products to the European New Approach Directives.
OMEGA will add the CE mark to every appropriate device upon certification.
The  information  contained  in  this  document  is  believed  to  be  correct,  but  OMEGA Engineering, Inc.
accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.

TRADEMARK NOTICE:

®

,

omega.com

®

,

and 

™ are  Trademarks  of

OMEGA ENGINEERING, INC.

®

Reviews: