2-15-(27)
EC Defect
Section 2-15
The screen for setting the angle of the arrow will be displayed.
6.
Align the arrow with the angle of the line.
Down/Right Keys:
Move the arrow clockwise.
Up/Left Keys:
Move the arrow counterclockwise.
CHECK
The line will not be extracted correctly if the arrow is rotated so that it is the
reverse of the arrow direction shown in step 3. Press the TRIG Key to re-
turn the arrow to the correct direction if the arrow direction has become un-
clear.
HELP
Arrow directions (edge codes) and angles: See page 2-15-(27).
7.
Press the ENT Key.
The screen for setting the permissible range will be displayed.
8.
Set the permissible angle range. The maximum setting is
45
.
Up/Left Keys:
Increase the range.
Down/Right Keys:
Decrease the range.
9.
Press the ENT Key.
The settings will be registered and the screen in (1.) will return.
Direction
Angle:180
Example
Direction
Latitude angle: 15