2-6-(12)
EC Position Compensation
Section 2-6
Inputting Parameters
Input the parameters in pixel units for the radius and latitude of the search cir-
cle.
1.
Select Radius.
The registration selections will be displayed.
2.
Select Input parameter.
The Input Parameter Settings Screen will be displayed.
3.
Make the settings for each item.
4.
Select End.
The settings will be registered and the screen in (1.) will return.
STEP 4: Registering Reference Positions
Register the reference position for position displacement compensation. Place
the measurement object in the correct position before executing reference
position registration.
Radius width (1 to 64)
Radius (3 to 512)
Measurement conditions
Search region
Radius
Reference registration
Judgement conditions
Clear
Position0(Circle)
Input figure
Input parameter
Input parameter
End
Radius
Latitude of radius
:
:
[ 50]
[20]