6-3-(15)
Host Link Serial Interface
Section 6-3
CHECK
Output numbers that have not been set, such as data 1 in the example above,
are omitted from the data output.
Example 2
The results for up to 7 data elements can be output at one time. If 8 or more
output numbers have been set, the data will be output in groups of 7 elements
max.
In this example, output numbers 0 through 7 have been set. The results for
data 0 to data 6 are output the first time and the results for data 7 are output
the second time.
Data 2
+4
0000
0000
0000
0000
Write flags (0000)
+5
0110
1001
0100
0011
Four lowest integer digits
+6
1111
0000
0000
0000
Sign and two highest integer digits
+7
0000
0010
1001
1000
Decimal point
Data
Write
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
Data
Write
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
First batch:
Data 0 to
data 6
+0
0000
0000
0000
0000
Write flags (0000)
+1
0000
0001
0100
0011
Measurement result
+2
0000
0000
0000
0000
+3
0000
0010
0101
0000
:
:
:
:
:
:
:
:
:
:
:
:
+(4
n)+0
0000
0000
0000
0000
Write flags (0000)
+(4
n)+1
0110
1001
0100
0011
Measurement result
+(4
n)+2
1111
0000
0000
0000
+(4
n)+3
0000
0010
1001
1000
:
:
:
:
:
:
:
:
:
:
:
:
Second
batch:
Data 7
+28
1111
0000
0000
0000
Write flags (1111)
+29
0000
0001
0110
0011
Measurement result
+30
0000
0000
0000
0000
+31
0000
0010
0101
0000
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...