![background image](http://html1.mh-extra.com/html/omron/f250-ume/f250-ume_software-manual_743525021.webp)
1-(13)
Menu Operations
Section 1-5
1-5-2
Screen Displays
The Application Software is operated by selecting functions from menus dis-
played on the screen. Familiarize yourself with each function before operating
the Controller.
Mode
Display
Meaning
SET
Used to set the inspection conditions.
MON (Monitor)
Used to check whether inspections are being performed correctly
under the set inspection conditions. The measurement results are
displayed on the monitor only. The results cannot be output to
external devices.
RUN
Performs inspection. The measurement results are output to an
external device via the parallel interface or serial interface.
SYS (System)
Used to set system conditions.
TOOL
Used to save settings and images to a computer as backup.
SAVE
Used to saves data to flash memory in the Controller. If new set-
tings have been made, be sure to save the data before quitting.
0.Scn 0=SET=
0.Camera image
1.
ENT:Set SFT+ESC:Edit
Scene Number
There are 32 screens. Setting
different measurement
conditions for each one allows
easy switching between
different setups.
Cursor Keys
The cursor is moved to the
desired function by pressing
the Cursor Keys.
A processing item is set for each
unit.
When a measurement command is
input, units are processed in order
from unit 0.
Mode
The current operating mode is
displayed.
The type of image shown on the
screen is displayed in Monitor and
Run Modes.
Refer to 5-5-1 Displaying
Stored Images.
Key Operations
Displays special key combinations at the bottom of the screen
when available.
“SFT” refers to the SHIFT Key. “SFT+ESC” indicates that the
ESC Key should be pressed while the SHIFT Key is pressed.
Sometimes the SFT Key display is abbreviated to just “S”.
Units
Содержание F250-UME
Страница 2: ...80 SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG HFHPEHU...
Страница 3: ...iii...
Страница 337: ...2 15 4 EC Defect Section 2 15 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 531: ...2 23 4 ECM Search Section 2 23 4 Press the ENT Key The settings will be registered and the screen in 1 will return...
Страница 748: ...2 49 5 Display Line Display Box Display Circle and Display Cursor Section 2 49...
Страница 798: ...4 44 Memory Card Operations Section 4 6...
Страница 998: ...7 18 Menu Hierarchy Section 7 6...