11-10
Diagnostic Messages
CLM01.4-LAP-01VRS
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
E R R O R
Hex Code 14
I D S
C h a r
F o r m a t
This error will occur if the optional IDS board is enabled, but the CLM
does not detect the connection of the IDS board.
The IDS board is enabled in parameter B002.
1.
The cable between the IDS board and the CLM connector X6 is
not installed properly.
2.
If the IDS board is connected, then the wiring and its layout to the
decade switch should be checked. Maximum cable length is 15m.
E R R O R
Hex Code 16
W r o n g
A x i s
N o .
This error occurs because the CLM program encountered a program
command with an illegal axis number.
E R R O R
Hex Code 17
H a r d w .
A x i s
3 & 4
The parameters for axis 3 or 4 are set but there is no 4 axis option
available
E R R O R
Hex Code 19
- Contact INDRAMAT Customer Service! -
C L M
+ / -
1 5
V o l t s
This error is an internal hardware fault in the CLM. The internal 15 Volts
power supply is defective.