CLM01.4-LAP-01VRS
Diagnostic Messages
11-13
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
E R R O R
Hex Code 35
= EOS command missing during "’Flying
M i s s i n g
E O S
C m d
Cutoff Operation"
The processing program did not end with the EOS command.
E R R O R
Hex Code 36
N o t
H o m e p o s i t i o n
Error message during ’Flying Cutoff Operation.’
When switching to Automatic Mode, the carriage is not in its home
position.
E R R O R
Hex Code 37
F i e l d b u s
T i m e o u t
Cyclic transmission of the process data via the fieldbus is monitored. The
CLM has not received a new telegram during the maximum cycle time
(Parameter B006).
E R R O R
Hex Code 38
= Logic Task Program Error
L o g i c
P r g .
E r r o r
1.
An invalid command is programmed in the Logic Task.
2.
An invalid input, output or flag number is programmed in the Logic
Task.
3.
No ’END’ command is programmed in the Logic Task.
4.
The positioning of the parentheses is wrong in the Logic Task.
E R R O R
Hex Code 39
= Logic Task Program Lost
L o g i c
P r g .
L o s t
The contents of one or more Logic Task program sets have been altered
without new data input by the user.
Õ
The contents of all Logic Task program sets must be checked.
Summary of Contents for CLM1.4
Page 117: ...7 20 Functions CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Page 205: ...9 42 Interfaces CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Page 213: ...10 8 Command Communications CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Page 233: ...11 20 Diagnostic Messages CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Page 272: ......
Page 273: ...Printed in the U S A Barcode...