CLM01.4-LAP-01VRS
Parameters
8-11
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
Ax06 Axis x Maximum Velocity
m a x .
V e
l o c i t y
A x
A x 0 6
1 2 3 4 5 6 . 7 8 9
Maximum velocity in IU/sec
The maximum velocity input here is the highest velocity to be used for
travel.
The maximum velocity may not be larger than the maximum possible
velocity, which is calculated as follows:
constant
Feed
60
Ax12)
(P.
Rpm
=
possible
Vmax
×
L:
Vmax
=
Maximum velocity
Rpm
=
Revolutions per minute
Fig. 8-4: Axis x Maximum Velocity
If the velocity is larger than ’Vmax possible,’ the error message ’Invalid
Input’ is shown on the display.
Input range:
from 0.100 to 50000.000 in IU/sec
Ax07 Axis x Jog Velocity
m a n .
V e l o c i t y
A x
A x 0 7
0 0 0 1 6 6 . 6 6 6
Velocity in Manual Mode in IU/sec
With the velocity entered here, the drive is moved using ’Jog forward’ or
’Jog reverse.’
Input range:
from 0.100 to 50000.000 in IU/sec
also:
Ax07 <= Ax06