8-42
Parameters
CLM01.4-LAP-01VRS
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
C002 Master Encoder 1, Measuring Wheel Encoder Feed Constant (VK)
M - W h e e l 1
V K
C 0 0 2
0 5 0 0 . 0 0 0 0 0
Feed constant of measuring wheel 1 in IU
Input range:
from 0.01000 to 5000.00000 in IU
C003 Master Encoder 1, Measuring Wheel Offset
M - W h e e l 1
O f f s e t
C 0 0 3
+ 1 2 3 4 5 . 6 7 8
This parameter currently has no function.
C004 Master Encoder 2, Measuring Wheel Encoder Data
In preparation
as in Parameter C000
C005 Master Encoder 2, Measuring Wheel Encoder Type
In preparation
as in Parameter C001
C006 Master Encoder 2, Measuring Wheel Encoder Feed Constant (VK)
In preparation
as in Parameter C002
C007 Master Encoder 2, Measuring Wheel Offset
In preparation
as in Parameter C003