CLM01.4-LAP-01VRS
Parameters
8-15
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
Ax12 Axis x Drive Sensitivity
D r i v e S e n s i t i v
A x
A x 1 2
0 1 0 0 0
0 9 . 0
Command voltage at maximum velocity in volts, with 1 decimal place
(00.5 to 10.0)
Max. encoder velocity in Rpm (0001 to 9999)
The maximum velocity Ax06 is calculated as follows:
Constant
Feed
60
Rpm
Vmax
×
=
Fig. 8-7: Maximum Velocity
For drive amplifiers with analog inputs
≤
10 V that limit the velocity
command value, the drive amplifier and the CLM should be calibrated at
9 V to ensure sufficient system resources at maximum velocity.