9-10
Interfaces
CLM01.4-LAP-01VRS
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
Run Task
Connector No. 4 / Pin No. 10:
Q0.01.1
This output shows that a program in Task 1, 2, 4 and 5 (when enabled) is
being processed. It is set when the CLM is in Automatic Mode, a start
signal was issued, and no Immediate Stop is present.
If the program was stopped (e.g. via the signal ’Immediate Stop,’ the ’JST’
command or switching to ’Manual’ Mode), the output is cleared.
A manual vector program does not cause the output to be set!
Connector No. 4 / Pin No. 14:
Q0.01.5
This output is set if a move command cannot be executed because, for
example, an interrupt or feed angle monitoring is present or an axis
enable signal is not present in Jog Mode.
Operating Modes
Connector No. 4 / Pin No. 3:
Q0.00.2
If the operating mode ’Parameter Input’ is accepted by the CLM, this
output is powered.
Connector No. 4 / Pin No. 2:
Q0.00.1
If the operating mode ’Automatic’ is accepted by the CLM, this output is
powered.
Connector No. 4 / Pin No. 1:
Q0.00.0
If the operating mode ’Homing’ is accepted by the CLM, this output is
powered.
Run Task
Inhibit Operation
Parameter Mode
Automatic Mode
Manual Mode/Automatic Mode
Summary of Contents for CLM1.4
Page 117: ...7 20 Functions CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Page 205: ...9 42 Interfaces CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Page 213: ...10 8 Command Communications CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Page 233: ...11 20 Diagnostic Messages CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Page 272: ......
Page 273: ...Printed in the U S A Barcode...