4-10
Display and Operating Devices
CLM01.4-LAP-01VRS
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
Operation Data
Automatic
In this display mode, the program instruction that is currently being
processed is displayed.
The first 3 tasks (if programmed) are displayed simultaneously. If Tasks 4
and 5 are also programmed, these can be displayed by pressing
or
.
The display in Automatic Mode is also valid for Manual Mode.
Operating Mode:
A = Automatic
E = Manual
F = Fault
M :
P r o g . S t a t u s
T a s k 1 :
0 0 0 0
J M P
T a s k 2 :
0 6 0 0
P O I
T a s k 3 :
2 4 0 0
A E A
Current user command
Current program instruction number
Operating Mode:
A = Automatic
E = Manual
F = Fault
M :
P r o g . S t a t u s
T a s k 4 :
1 0 0 0
J M P
T a s k 5 :
2 6 0 0
P O I
Current user command
Current program instruction number
Summary of Contents for CLM1.4