8-46
Parameters
CLM01.4-LAP-01VRS
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
8.6
Minimum and Maximum Values for Parameter Input
Parameter
Designation
Min. Data
Max. Data
Ax 01
Feed Constant
IU
0.0100
5000.00000
Ax 05
Modulo Value
IU
Ax 06
Maximum Velocity
IU/sec
0.100
50000.000
Ax 07
Jog Velocity
IU/sec
0.100
50000.000
Ax 08
Acceleration Rate
IU/sec
2
1
999999
Ax 10
Jerk Constant
sec
0.000
1.024
Ax 11
Kv Factor
0.01
20.00
Ax 12
Drive Sensitivity
Volts
0.5
10.0
Ax 19
Encoder Data
100
5000
C000
Master Encoder 1 Data
100
5000
C002
Master Encoder 1 Feed Constant
IU
0.0100
5000.00000
C004
Master Encoder 2 Data
100
5000
C006
Master Encoder 2 Feed Constant
IU
0.0100
5000.00000
Fig. 8-13: Parameter Input Range