CLM01.4-LAP-01VRS
Writing the User Program
5-9
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
Axis Variables
The axis variables are read-only.
They exist for each axis and are assigned to variables V1xx – V4xx.
No.
Definition
Vx00
Absolute position value of motor encoder (IU)
Vx01
Position Command Value
Vx02
Reserved
Vx03
Lag Distance
Vx04
Actual velocity [IU/sec]
Legend: x = Axis Number