Appendix - 113
MELSEC-Q
APPENDICES
(b) Error and Solution, Intelligent Module Information
• Error and Solution
Details of the selected in the "Error History List" and its corrective action
are displayed.
• Intelligent Module Information
The QD75P N/QD75D N status when the error selected in the "Error
History List" occurred is displayed.
For the QD75P N/QD75D N, the following contents are displayed.
Item Description
Start axis
The axis No. requested to start is stored.
Positioning start No.
The positioning start No. is stored.
Axis in which the error occurred
The axis No. in which the error occurred is stored.
Axis error occurrence (Data No.)
The data No. in which the error occurred is stored.
Current feed value
The current feed value (at the time of error) of the error axis is stored.
Input signals with PLC CPU(X0 --
XF)
The status of input signals (X0 to XF) (at the time of error) is stored (in hexadecimal).
Input signals with PLC CPU(X10 --
X1F)
The status of input signals (X10 to X1F) (at the time of error) is stored (in
hexadecimal).
Output signals with PLC CPU(Y0 --
YF)
The status of output signals (Y0 to YF) (at the time of error) is stored (in
hexadecimal).
Output signals with PLC CPU(Y10
-- Y1F)
The status of output signals (Y10 to Y1F) (at the time of error) is stored (in
hexadecimal).
• Axis 1 drive unit READY signal
• Axis 1 upper limit signal
• Axis 1 lower limit signal
• Axis 1 stop signal
• Axis 1 external command signal
• Axis 1 near-point dog signal
• Axis 1 zero signal
The status of axis 1 external input signals (at the time of error) is stored.
• Axis 2 drive unit READY signal
• Axis 2 upper limit signal
• Axis 2 lower limit signal
• Axis 2 stop signal
• Axis 2 external command signal
• Axis 2 near-point dog signal
• Axis 2 zero signal
The status of axis 2 external input signals (at the time of error) is stored.
• Axis 3 drive unit READY signal
• Axis 3 upper limit signal
• Axis 3 lower limit signal
• Axis 3 stop signal
• Axis 3 external command signal
• Axis 3 near-point dog signal
• Axis 3 zero signal
The status of axis 3 external input signals (at the time of error) is stored.
• Axis 4 drive unit READY signal
• Axis 4 upper limit signal
• Axis 4 lower limit signal
• Axis 4 stop signal
• Axis 4 external command signal
• Axis 4 near-point dog signal
• Axis 4 zero signal
The status of axis 4 external input signals (at the time of error) is stored.
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......