6 - 8
MELSEC-Q
6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
Device
Device
name
Axis 1 Axis 2 Axis 3 Axis 4
Application
Details when ON
M34
ZP.TEACH1 instruction complete device ZP.TEACH1 instruction completed
M35
ZP.TEACH1 instruction failure device
ZP.TEACH1 instruction failed
M36
ZP.PINIT instruction complete device
ZP.PINIT instruction completed
M37
ZP.PINIT instruction failure device
ZP.PINIT instruction failed
M38
ZP.PFWRT instruction complete device ZP.PFWRT instruction completed
M39
ZP.PFWRT instruction failure device
ZP.PFWRT instruction failed
M40
Absolute position restoration instruction
pulse
Absolute position restoration
commanded
M41
Absolute position restoration instruction
storage
Absolute position restoration
instruction held
M42
Z.ABRST instruction complete device
Z.ABRST instruction completed
M43
Z.ABRST instruction failure evice
Z.ABRST instruction failed
M50
Basic parameter 1 setting complete
device
Basic parameter 1 setting completed
Internal relay
M51
—
OPR basic parameter setting complete
device
OPR basic parameter setting
completed
(2) Data resisters and timers
Device
Device
name
Axis 1 Axis 2 Axis 3 Axis 4
Application
Details of storage
D0
OPR request flag
(
Md.31
Status (bit 3))
D1
Speed (low-order 16 bits)
D2
Speed (high-order 16 bits)
(
Cd.25
Position-speed switching
control speed change resister)
D3
Movement amount (low-order 16 bits)
D4
Movement amount (high-order 16 bits)
(
Cd.23
Speed-position switching
control movement amount change
resister)
D5
Inching movement amount
(
Cd.16
Inching movement amount)
D6
JOG operation speed (low-order 16 bits)
D7
JOG operation speed (high-order 16
bits)
(
Cd.17
JOG operation speed)
D8
Manual pulse generator 1 pulse input
magnification (low-order)
D9
Manual pulse generator 1 pulse input
magnification (high-order)
(
Cd.20
Manual pulse generator 1
pulse input magnification)
D10
Manual pulse generator operation
enable
(
Cd.21
Manual pulse generator
enable flag)
D11
Speed change value (low-order 16 bits)
D12
Speed change value (high-order 16 bits)
(
Cd.14
New speed value)
D13
Speed change request
(
Cd.15
Speed change request)
Data register
D14
—
Override value
(
Cd.13
Positioning operation speed
override)
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...