9 - 3
MELSEC-Q
9 MAJOR POSITIONING CONTROL
Major positioning control
Da.2 Control system
Details
Speed-position switching control
Forward run
speed/position
Reverse run
speed/position
The control is continued as position control (positioning for
the designated address or movement amount) by turning
ON the "speed-position switching signal" after first carrying
out speed control.
Position-speed switching control
Forward run
position/speed
Reverse run
position/speed
The control is continued as speed control by turning ON
the "position-speed switching signal" after first carrying out
position control.
NOP
instruction
NOP instruction
A nonexecutable control system. When this instruction is
set, the operation is transferred to the next data operation,
and the instruction is not executed.
Current value
changing
Current value changing
The current feed value (
Md.20
) is changed to an address
set in the positioning data.
This can be carried out by either of the following 2
methods.
(The machine feed value cannot be changed.)
•
Current value changing using the control system
•
Current value changing using the current value
changing start No. (No. 9003).
JUMP
instruction
JUMP instruction
An unconditional or conditional JUMP is carried out to a
designated positioning data No.
LOOP
LOOP
A repeat control is carried out by repeat LOOP to LEND.
Other control
LEND LEND
Control is returned to the top of the repeat control by
repeat LOOP to LEND. After the repeat operation is
completed specified times, the next positioning data is run.
In "2-axis linear interpolation control", "3-axis linear interpolation control", "4-axis linear interpolation control", "2-axis
fixed-feed control", "3-axis fixed-feed control", "4-axis fixed-feed control", "2-axis circular interpolation control", "2-axis
speed control", "3-axis speed control" and "4-axis speed control", control is carried out so that linear and arc paths are
drawn using a motor set in two or more axes directions. This kind of control is called "interpolation control". (Refer to
Section 9.1.6 "Interpolation control" for details.)
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......