9 - 80
MELSEC-Q
9 MAJOR POSITIONING CONTROL
Positioning data setting examples
The following table shows the setting examples when "3-axis speed control
(forward run: speed 3)" is set in the positioning data No. 1 of axis 1 (reference
axis).
Axis
Setting item
Axis 1
(reference
axis) setting
example
Axis 2
(interpolation
axis) setting
example
Axis 3
(interpolation
axis) setting
example
Setting details
Da.1
Operation pattern
Positioning
complete
– –
Setting other than "Positioning complete" is
not possible in speed control.
Da.2
Control system
Forward run
speed 3
–
–
Set 3-axis speed control.
Da.3
Acceleration time
No.
1 – –
Designate the value set in " Pr.25
Acceleration time 1" as the acceleration time
at start.
Da.4
Deceleration time
No.
0 – –
Designate the value set in " Pr.10
Deceleration time 0" as the deceleration time
at deceleration.
Da.5
Axis to be
interpolated
– – –
Setting not required (setting value will be
ignored).
When axis 1 is used as a reference axis, the
interpolation axes are axes 2 and 3.
Da.6
Positioning address/
movement amount
– – –
Setting not required (setting value will be
ignored).
Da.7
Arc address
–
–
–
Setting not required (setting value will be
ignored).
Da.8
Command speed
6000.00
mm/min
3000.00
mm/min
2000.00
mm/min
Set the speed to be commanded.
Da.9
Dwell time
–
–
–
Setting not required (setting value will be
ignored).
Axis 1 Positioning data N
o. 1
Da.10
M code
10
–
–
Set this when other sub operation commands
are issued in combination with the No. 1
positioning data. (" Pr.18 M code ON signal
output timing" setting only possible in the
WITH mode.)
Refer to Section 5.3 "List of positioning data" for information on the setting details.
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......