9 - 69
MELSEC-Q
9 MAJOR POSITIONING CONTROL
In circular interpolation control with center point designation, an angular velocity is
calculated on the assumption that operation is carried out at a command speed on
the arc using the radius calculated from the start point address and center point
address, and the radius is compensated in proportion to the angular velocity
deviated from that at the start point.
Thus, when there is a difference (error) between a radius calculated from the start
point address and center point address (start point radius) and a radius calculated
from the end point address and center point address (end point radius), the
composite speed differs from the command speed as follows.
Start point radius > End point radius: As compared with the speed without error,
the speed becomes slower as end point
address is reached.
Start point radius < End point radius: As compared with the speed without error,
the speed becomes faster as end point
address is reached.
Restrictions
(1) 2-axis circular interpolation control cannot be set in the following cases.
•
When "degree" is set in "
Pr.1
Unit setting"
•
When the units set in "
Pr.1
Unit setting" are different for the reference axis
and interpolation axis. ("mm" and "inch" combinations are possible.)
•
When "reference axis speed" is set in "
Pr.20
Interpolation speed
designation method"
(2) An error will occur and the positioning start will not be possible in the following
cases. The machine will immediately stop if the error is detected during
positioning control.
•
When the radius exceeds "536870912 (=2
29
)". (The maximum radius for
which circular interpolation control is possible is "536870912 (=2
29
)"
... An error "Outside radius range" (error code: 544) will occur at positioning
start.
•
When the end point address is outside the range of -2147483648(-2
31
) to
2147483647(2
31
-1)
... An error "End point setting error" (error code: 526) will occur.
•
When the start point address is the same as the center point address
... An error "Center point setting error" (error code: 527) will occur.
•
When the end point address is the same as the center point address
... An error "Center point setting error" (error code: 527) will occur.
•
When the center point address is outside the range of -2147483648(-2
31
) to
2147483647(2
31
-1)
... An error "Center point setting error" (error code: 527) will occur.
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......