5 - 79
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Da.18 Parameter 1
Set the parameters as required for the "
Da.16
Condition operator".
Da.16
Condition operator
Setting value
Setting details
01
H
:
∗∗
=P1
02
H
:
∗∗≠
P1
03
H
:
∗∗≤
P1
04
H
:
∗∗≥
P1
05
H
: P1
≤∗∗≤
P2
06
H
:
∗∗≤
P1, P2
≤∗∗
Value
The value of P1 should be equal to or smaller than the value of
P2. (P1
≤
P2)
If P1 is greater than P2 (P1>P2), the error "Condition data error"
(error code 533) will occur.
07
H
: DEV=ON
08
H
: DEV=OFF
Value
(bit No.)
Set the device bit No.
X: 0
H
to 1
H
, 4
H
to 17
H
Y: 0, 4
H
to 17
H
10
H
: Axis 1 selected
E0
H
: Axes 2, 3, and 4 selected
Value
(positioning data No.)
Set the positioning data No. for starting axis 1 and/or axis 2.
Low-order 16-bit
: Axis 1 positioning data No. 1 to 600 (01
H
to 258
H
)
High-order 16-bit
: Axis 2 positioning data No. 1 to 600 (01
H
to 258
H
)
Da.19 Parameter 2
Set the parameters as required for the "
Da.16
Condition operator".
Da.16
Condition operator
Setting value
Setting details
01
H
:
∗∗
=P1
02
H
:
∗∗≠
P1
03
H
:
∗∗≤
P1
04
H
:
∗∗≥
P1
—
Not used. (No need to be set.)
05
H
: P1
≤∗∗≤
P2
06
H
:
∗∗≤
P1, P2
≤∗∗
Value
The value of P2 should be equal to or greater than the value of
P1. (P1
≤
P2)
If P1 is greater than P2 (P1>P2), the error "Condition data error"
(error code 533) will occur.
07
H
: DEV=ON
08
H
: DEV=OFF
10
H
: Axis 1 selected
20
H
: Axis 2 selected
30
H
: Axes 1 and 2 selected
—
Not used. (No need to be set.)
40
H
: Axis 3 selected
50
H
: Axes 1 and 3 selected
60
H
: Axes 2 and 3 selected
70
H
: Axes 1, 2, and 3 selected
80
H
: Axis 4 selected
90
H
: Axes 1 and 4 selected
A0
H
: Axes 2 and 4 selected
B0
H
: Axes 1, 2, and 4 selected
C0
H
: Axes 3 and 4 selected
D0
H
: Axes 1, 3, and 4 selected
E0
H
: Axes 2, 3, and 4 selected
Value
(positioning data No.)
Set the positioning data No. for starting axis 3 and/or axis 4.
Low-order 16-bit
: Axis 3 positioning data No. 1 to 600 (01
H
to 258
H
)
High-order 16-bit
: Axis 4 positioning data No. 1 to 600 (01
H
to 258
H
)
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......