12.7.9 Stop command processing for deceleration stop function
The "stop command processing for deceleration stop function" is provided to set the
deceleration curve if a stop cause occurs during deceleration stop processing
(including automatic deceleration).
This function is valid for both trapezoidal and S-curve
acceleration/deceleration processing methods.
(For the stop cause, refer to Section 1.2.3 Outline of stopping.)
The "stop command processing for deceleration stop function"
performs the following two operations:
(1) Deceleration curve re-processing
Re-processes a deceleration curve starting from the speed at stop cause
occurrence to stop, according to the preset deceleration time.
(2) Deceleration curve continuation
Continues the current deceleration curve after a stop cause has occurred.
This section explains the "stop command processing for deceleration stop function" as
follows:
[1] Control details
[2] Control precautions
[3] Setting method
[1] Control details
The operation of "stop command processing for deceleration stop function" is
explained below.
(1) Deceleration curve re-processing
A deceleration curve is re-processed starting from the speed at stop cause
occurrence to stop, according to the preset deceleration time.
If a stop cause occurs during automatic deceleration of position control, the
deceleration stop processing stops as soon as the target has reached the
positioning address specified in the positioning data that is currently
executed.
Stop cause
occurrence
t
V
Deceleration stop
processing (automatic
deceleration) start
Deceleration curve according
to preset deceleration time
Deceleration curve when stop
cause does not occur
Immediate stop at the specified
positioning address
Fig. 12.56 Deceleration curve re-processing operation (for position control or S-curve
acceleration/deceleration processing)
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......